For shared equipment, the key question in cleaning validation is: how much residue can be carried over from one product to the next at most? This value is called MAC (Maximum Allowable Carryover) or MACO and is the basis for all acceptance criteria.
With EMA's guideline on health-based exposure limits for shared facilities, limits are expected to be derived from PDE (Permitted Daily Exposure) values based on toxicological data. The basic calculation is:
MACO = (PDEprevious product × MBS) / TDDnext product
The classic "1/1000 of the dose" and "10 ppm" criteria can still be used as an additional safety check, but they are no longer accepted as a justification on their own.
The calculated MACO is divided by the shared product-contact surface area to give a limit per unit area; multiplying this by the swab area gives the acceptance criterion per sample. Results from recovery studies must be reflected in this criterion.
Swab sampling allows samples to be taken directly from the hardest-to-clean (worst-case) locations. Rinse sampling represents large, closed or hard-to-reach surfaces. In most cases, using both methods together with a justified sampling plan is the most robust approach.